Table A: Building Energy Ratings by Period of Construction (Non-Domestic)
% of row
Period of constructionEnergy rating 
ABCDEFGTotal
1900-19770730261691313,199
1978-199901137231271011,975
2000-200401644199487,219
2005-20091203716751513,139
2010-201482829168371,903
2015-20182636178319932

26% of non-domestic construction between 2015 and 2018 was rated "A"

Figure 1: Building Energy Ratings by Period of Construction (Non-Domestic) 1900-2018
go to full release

Building Energy Ratings (BER) audits were conducted for 932 non-domestic buildings constructed between 2015 and 2018 (see Table A). Over one quarter (26%) of these buildings received an “A” rating compared with 8% of non-domestic buildings constructed during 2010 to 2014 (see Figure 1). In contrast, 96% of domestic dwellings constructed between 2015-2018 received an "A" rating (separate CSO release). 

There were 52,736 non-domestic BER audits conducted in the period 2009 to 2018 (see Table 1). The profile of non-domestic BER audits conducted since 2009 was 1% awarded an "A" rating, 14% a "B" rating, and 35% with a “C” rating (see Table 3).

The most energy efficient building types audited during 2009-2018 were Schools and colleges with 24% awarded an “A” rating (see Table 3). The second most energy efficient buildings were Nursing residential homes and hostels with 7% rated “A”. The least energy efficient building types, defined by a “G” rating, were Workshops and maintenance depots (22%) followed by Warehouses (14%) and Office buildings (13%) (see Figure 3).

The highest proportion of combined “A” and “B” ratings were in County Offaly at 21% (see Table 4). Kilkenny and Sligo had the highest proportion of “G” rated buildings at 17% each (see Table 4).

Dublin 15 had the highest proportion of combined “A” and “B” ratings at 25% compared with 19% for Dublin 18 (see Table 5). The highest proportion of “G” ratings was 17% in Dublin postal districts 5 and 8 (see Table 5).

The average floor area of all audited non-domestic dwellings was 670 square metres (see Table 10). This average size varied from 3,350 square metres for hotels to 303 square metres for retail premises.

BER Ratings
A0.542
B10.91
B22.185
B33.882
C16.422
C26.204
C35.028
D16.186
D24.715
E13.181
E22.489
F3.302
G5.987
ABCDEFG
Retail01442179612
Office19312513813
Restaurant/public house0729361864
Hotel0164326843
Warehouses018341910614
Workshops/maintenance depot092323141022
Industrial process building2362616938
Hospitals and primary health care6152320141012
Community/day centre3273017958
Nursing residential homes and hostels7393015413
Schools and colleges24262317524
Sports facilities2292919868
Other217241811820
Table 1 Building Energy Ratings Certificates (Non-Domestic) 2009-2018
number
Period2009201020112012201320142015201620172018Total
January451941501934445906343993393623,350
February1473261661569466217435535364764,670
March2072282012248487408076476984665,066
April1652301621788617966336654553674,512
May2401892012047888836616475314554,799
June3481841981637668576865974623814,642
July408193190243752841595561487 4,270
August266287173213575785563587453 3,902
September265221218245693998673683595 4,591
October236206207289863882682640620 4,625
November307303223328713964572530512 4,452
December337193211309574853467436477 3,857
            
Total2,9712,7542,3002,7458,8239,8107,7166,9456,1652,50752,736
Table 2 Building Energy Ratings by Year (Non-Domestic) 2009-2018
number
YearEnergy Rating Total
AB1B2B3C1C2C3D1D2E1E2FG
200928117241385447362278278224106851401282,819
201021551812663453562873052051271221291732,572
20114666120208292237214270164110941281412,090
201237511132033753332843242501721181542172,631
2013481153505851,1231,0958681,0358154953595411,0388,467
2014431143046641,2171,1458991,2029066145126511,2819,552
2015811292575189309197198836964984015171,0047,552
2016881022364707717996378406254823764829086,816
20171011162644186676655987825753972983987856,064
201849451191652552932442672551801241623122,470
               
Total5429102,1853,8826,4226,2045,0286,1864,7153,1812,4893,3025,98751,033
Table 3 Building Energy Ratings by Type of Building (Non-Domestic) 2009-2018
% of row 
Building TypeEnergy Rating Total
AB1B2B3C1C2C3D1D2E1E2FG
Retail01491715101075461219,514
Office12258111213117681311,602
Restaurant/public house0124810111917117644,758
Hotel027814151416106343738
Warehouses026913129118556147,092
Workshops/maintenance depot01357781398610222,074
Industrial process building2131210129611554381,111
Hospitals and primary health care6466788119771012873
Community/day centre341112131071075458840
Nursing residential homes and hostels77141813106783113401
Schools and colleges2478109771072224729
Sports facilities25111312981185268447
Other2566107611657820854
               
Total12481312101296561251,033
Table 4 Building Energy Ratings by County (Non-Domestic) 2009-2018
% of row    
CountyEnergy Rating Total
AB1B2B3C1C2C3D1D2E1E2FG
Carlow0271016121010755213651
Dublin 01-24124712121113107561113,950
Dublin County1247151310129556103,672
Kildare3259121310108555122,054
Kilkenny137714108101055417766
Laois225121211812885413598
Longford115811121011886911389
Louth124511128148668151,406
Meath1269131211118555131,685
Offaly237101112121475469582
Westmeath026816138111065591,123
Wexford213611139119678141,420
Wicklow1351112118128657101,491
Clare0247111191312669111,415
Cork City014512149121264614479
Cork County1248131311129646114,578
Kerry024913149109647121,286
Limerick City1134121371410751014427
Limerick County114813139139667111,819
Tipperary1248161110129757111,394
Waterford City00371514111088588616
Waterford County22691211811855514785
Galway City115510141212977513592
Galway County12581112101110658122,546
Leitrim21612121119117469227
Mayo115812129119657131,349
Roscommon114710109131084915524
Sligo114615109111073717781
Cavan11471212812986713638
Donegal135811119138756121,294
Monaghan1349118911776616496
               
Total12481312101296561251,033
– No non-domestic unit received this BER rating in this county
Table 5 Building Energy Ratings by Dublin Postal District (Non-Domestic) 2009-2018
% of row 
Dublin Postal DistrictEnergy Rating Total
AB1B2B3C1C2C3D1D2E1E2FG
Dublin 11125121191511639151,233
Dublin 21134911111312868112,092
Dublin 311681511157851013340
Dublin 4145581012151076610603
Dublin 5112913131011774617272
Dublin 60146109101012971013412
Dublin 6W123715715101061116200
Dublin 70234121212131165614623
Dublin 8113411911131076617866
Dublin 911581412121486479549
Dublin 101247815101299868224
Dublin 1125911141111119458664
Dublin 1201351212111710746101,170
Dublin 1322101413111187938180
Dublin 14026715129131153710434
Dublin 151361517161010732361,058
Dublin 1614413139121463713179
Dublin 1702371812141186647360
Dublin 181549914121496448765
Dublin 20266129911126861265
Dublin 2211791516101294447563
Dublin 241249161210129534131,098
               
Total124712121113107561113,950
– No non-domestic unit received this BER rating in this Dublin postal district
Table 6 Building Energy Ratings by Main Space Heating System Fuel (Non-Domestic) 2009-2018
% of row 
Heating System FuelEnergy Rating Total
AB1B2B3C1C2C3D1D2E1E2FG
Mains Gas23710121081086441413,334
Heating Oil1258121211161275545,123
Electricity01361313101296581231,191
LPG4412131512101074333914
Other47510787101086711471
               
Total12481312101296561251,033
Table 7 Main Space Heating System Fuel by County (Non-Domestic) 2009-2018
% of row 
CountyHeating System FuelTotal
Mains GasHeating OilElectricityLPGOther
Carlow2796021651
Dublin 01-24384570013,950
Dublin County36559013,672
Kildare27864112,054
Kilkenny27135621766
Laois25165712598
Longford10236061389
Louth30861111,406
Meath291158101,685
Offaly18195922582
Westmeath181661311,123
Wexford101568521,420
Wicklow27962111,491
Clare211857311,415
Cork City313641479
Cork County25865214,578
Kerry91568611,286
Limerick City262720427
Limerick County25963111,819
Tipperary181861211,394
Waterford City3146122616
Waterford County24106132785
Galway City1078210592
Galway County111472312,546
Leitrim6286041227
Mayo92067411,349
Roscommon12235842524
Sligo8186751781
Cavan13195882638
Donegal112754621,294
Monaghan16205643496
       
Total2610612151,033
– No non-domestic unit indicated the usage of this main space heating fuel type for this county
Table 8 Main Space Heating System Fuel by Type of Building (Non-Domestic) 2009-2018
% of row 
Building TypeHeating System FuelTotal
Mains GasHeating OilElectricityLPGOther
Retail174781119,514
Office327601111,602
Restaurant/public house282441524,758
Hotel453012121738
Warehouses321155217,092
Workshops/maintenance depot261455312,074
Industrial process building302737331,111
Hospitals and primary health care31125521873
Community/day centre36263241840
Nursing residential homes and hostels412915123401
Schools and colleges42262463729
Sports facilities4194352447
Other31115242854
       
Total2610612151,033
Table 9 Main Ventilation System by Type of Building (Non-Domestic) 2009-2018
% of row 
Building TypeMain Ventilation SystemTotal
Air ConditioningMechanical VentilationNatural Ventilation
Retail4744919,514
Office3565911,602
Restaurant/public house3411564,758
Hotel26866738
Warehouses146807,092
Workshops/maintenance depot155802,074
Industrial process building1912691,111
Hospitals and primary health care21673873
Community/day centre7786840
Nursing residential homes and hostels1792401
Schools and colleges6886729
Sports facilities301456447
Other19675854
     
Total3366151,033
Table 10 Average Floor Area by Type of Building and County (Non-Domestic) 2009-2018
              m2
CountyRetailOfficeRestaurant/ public houseHotelWarehousesWorkshops/ maintenance depotIndustrial process buildingHospitals and primary health careCommunity/ day centreNursing residential homes and hostelsSchools and collegesSports facilitiesOtherAll building types
Carlow4443173752,5888976803,0692392181,340988707853602
Dublin 01-243621,1373344,1051,3565802,7176823771,4321,8591,382959894
Dublin County2655163525,3981,3961,2053,8283874401,8792,3721,0111,428674
Kildare2253773784,2239905957,1066772812,3561,4681,321493628
Kilkenny2842752812,5591,1796741,4863032311,269976544194504
Laois3312562735,7958975464,3166832501,5162,2611,4891,871598
Longford3592602581,1671,1786486,3774244272,019574707206638
Louth3115543184,6951,2065914,2483712041,4501,5131,917854678
Meath2413852954,0629035351,7795392811,5251,6801,016270546
Offaly3034412291,9499606581,6327613121,5852,478258139593
Westmeath3015372462,2211,4686153,3328192601,1061,8391,053309586
Wexford2974662712,7638036512,0744733641,3471,459689732523
Wicklow2143022872,2286904262,0935413061,8051,717778280467
Clare2194892992,2319424402,3612002546341,020503492581
Cork City3806462124011,2624292,705163132757948533545
Cork County2876042693,4899804793,2035003491,3071,534831740588
Kerry2632792732,9066803033,3573892697601,077467328494
Limerick City2564782717,6309663651,4544964671,5218546773,383552
Limerick County2864482874,7631,1774453,3119014111,8442,4881,051973673
Tipperary2933412482,5091,6814493,7365443221,1151,105576211627
Waterford City2764463573,7857666982,075127659592666342929517
Waterford County6373202823,3951,3326583,8791,0531541,6101,2126991,114834
Galway City2873322034,0505943073,4803006561,4902,972447629530
Galway County2854172673,6431,1134801,8134432451,8901,302988449595
Leitrim2469142851,2805856328783968691,29855499
Mayo2612642843,6149166261,9169932631,380547624515483
Roscommon2714362541,9448155433,8877894931,3794376341,064486
Sligo3194042901,2229474522,8281,0372682,1371,510665883538
Cavan2303772472,8066234041,7093833523,0521,077621369419
Donegal2503883142,2551,1974642,6845324109681,031776565554
Monaghan2981633675,1821,2527141,7081425231,1961,852946880623
               
All3037162973,3501,1515782,8745563351,4441,548969755670
Table 11 Average Primary Energy Use by Type of Building and County (Non-Domestic) 2009-2018
kWh/m2/year
CountyRetailOfficeRestaurant/ public houseHotelWarehousesWorkshops/ maintenance depotIndustrial process buildingHospitals and primary health careCommunity/ day centreNursing residential homes and hostelsSchools and collegesSports facilitiesOtherAll building types
Carlow1,4395868386267448471,022473442448185651741966
Dublin 01-241,0684911,0376094376837353964963842791,176902594
Dublin County1,1105231,0156223446497704573764261491,046749600
Kildare1,2287608991,0044767586862793984631838361,188737
Kilkenny1,2259398885954586676344563614832761,425830768
Laois1,409848948501440793923243438457137987928824
Longford1,3669601,131726533975806347767314234627857869
Louth1,077574967631731770907373557399111772583778
Meath1,1775091,0006266189447762813524521831,597625723
Offaly8814539655595348246061984504231451,167668591
Westmeath1,0237069757495421,4075723534574121595991,440730
Wexford1,5905279698355229585025441,1456041541,191860855
Wicklow9676171,010808399667577381487452172789805630
Clare1,1606319406515927427281,8695656385051,319848752
Cork City1,181519968691599873469692494462965636764
Cork County1,1265229896585266145325434885751681,018702671
Kerry9977539726216216619425093904822361,012797761
Limerick City1,0831,6091,058502730748835353487944281766241934
Limerick County1,1217751,038674720664936478390362193788927813
Tipperary9927289367144179058002536443902391,091894714
Waterford City1,3745831,0217453886337594923812483611,192881751
Waterford County1,3546211,140730613554477401781349215996278843
Galway City1,1006901,2394855437388843153322681351,074820732
Galway County1,151725907579800721824328411370180869849777
Leitrim9147538548519995899714164961481,175764
Mayo1,1327959185625366907012203363953456262,666780
Roscommon1,9664661,1146376386056562947394374101,157639974
Sligo1,5799129535929846028853174625342501,1976881,006
Cavan9966201,044646685685809355573405252762957736
Donegal1,0985911,001661651853629340375556182732636730
Monaghan1,0416078567674381,270699575344325212946224702
               
All1,1515459906505127247334014944422111,022832688
Table 12 Average Carbon Dioxide Emissions by Type of Building and County (Non-Domestic) 2009-2018
kgCO2/m2/year
CountyRetailOfficeRestaurant/ public houseHotelWarehousesWorkshops/ maintenance depotIndustrial process buildingHospitals and primary health careCommunity/ day centreNursing residential homes and hostelsSchools and collegesSports facilitiesOtherAll building types
Carlow341138193142176194240110999441147175227
Dublin 01-24252112238134100156169901128160254211136
Dublin County26111923213979142172100839232229173137
Kildare289177208229110176161639110540181278171
Kilkenny2902202091271061551501028111463334199179
Laois3341982241101041842185310110530189210192
Longford325229269167127223191811827357148194206
Louth253132226143169177210861258624175137180
Meath27711823413714522018364799843360140168
Offaly210106229123124196144441069733278155139
Westmeath242166231170125331135811028535139341171
Wexford37812223019412322811912727114236216204201
Wicklow227142237185911571358611110238173184146
Clare274148221150138170168439132144119313199175
Cork City280118222145136197110160109105213142177
Cork County26612123014612214312412511412238216162156
Kerry2361782311411461572251198811356241190179
Limerick City257379246107171178185811082256418254218
Limerick County265181243142167156220106917844184215189
Tipperary23517222116098207188581539055254216168
Waterford City32513423516691145173111775878275204174
Waterford County32114526915314212911089176734621763196
Galway City26216429211112917521175756429232194173
Galway County27317221513118917019274978241197199182
Leitrim2181792032042401302319912133280182
Mayo26918721813112716516550808682147631184
Roscommon4681082651471511441586118010292264148230
Sligo3762152271392321382117411212460234155238
Cavan236147247149161158191821356760181213173
Donegal26114023915715419714378909442173150171
Monaghan2461442031769930015713879743819938161
               
All272125231146119167171911149747224194159
Table 13 Building Energy Ratings by Period of Construction (Non-Domestic) 2009-2018
% of row 
Period of ConstructionEnergy Rating Total
AB1B2B3C1C2C3D1D2E1E2FG
1900-19290013891015139710125,978
1930-19490024101291511778131,440
1950-196601251010101311978142,764
1967-197701351012101311868133,017
1978-198202251111111310969132,595
1983-19930137131291310767124,642
1994-1999014916151114954564,738
2000-20040151016151211854487,219
2005-2009127111413101074351513,139
2010-201488911129810644371,903
2015-20182616119854432119932
               
Total12481312101296561248,367
Table 14 Main Space Heating System Fuel by Period of Construction (Non-Domestic) 2009-2018
% of row  
Period of ConstructionFuel TypeTotal
Mains GasHeating OilElectricityLPGOther
1900-1929191563125,978
1930-1949181763211,440
1950-1966231658112,764
1967-1977261953213,017
1978-1982241757212,595
1983-1993241065114,642
1994-199928763114,738
2000-200428565207,219
2005-2009315622113,139
2010-2014301351421,903
2015-20184364551932
       
Total2610612148,367

Background Notes

Non-Domestic Building Energy Ratings

Introduction

The European Union Energy Performance of Buildings Directive (EPBD) contains a range of provisions to improve the energy performance of new and existing buildings. The EPBD obliges specific forms of information and advice on energy performance to be provided to building purchasers, tenants and users for consideration in property transactions. A Building Energy Rating (BER) is an indication of the energy performance of a building represented in units of kWh/m2/year. A BER is based on the characteristics of major components of the building. The BER certificate indicates the annual primary energy usage and carbon dioxide emissions associated with the provision of space heating, water heating, ventilation, lighting, and associated pumps and fans. The average annual primary energy use figures and carbon dioxide emissions are not based on actual energy use and emissions data.

These Background notes provide a very general overview together with some specific information on the detailed tables in the release. The SEAI website should be consulted for detailed information on the non-domestic energy assessment procedure (NEAP), see http://www.seai.ie/Your_Building/BER/Non_Domestic_buildings/Non_domestic_Energy_Assessment_Procedure_NEAP_/

Revisions

The figures in this release will be updated on a quarterly basis. Changes to data for the previous quarters will arise mainly from some buildings having another BER audit undertaken and the previous certificate being marked as expired. The difference in the number of BER certificates included in Tables 1 and 2 gives an indication of the number of buildings that have had more than one BER audit undertaken.

Coverage

Full site surveys have to be carried out for New-final and Existing building assessments. New-provisional ratings do not require a site survey as the assessment is done based on design stage plans – new provisional ratings have been excluded from this release. Some buildings are excluded from the EPBD requirements: national monuments; protected structures; places of worship; temporary buildings; industrial and agricultural buildings not intended for occupancy and below a specified installed heating capacity; and buildings with a total useful floor area of less than 50 square metres. Short-term lettings are not exempt.

A BER for new non-domestic buildings was introduced in July 2008 and for renting of existing non-domestic buildings in January 2009. New regulations came into effect in January 2013 requiring the inclusion of BER information in property sale and rental advertisements.

National representativeness

The data have not been adjusted to represent all non-domestic buildings in the State and hence the tables only represents buildings that have been assessed.

Definitions

The BER rating scale is divided into categories from G (largest primary energy usage) to an A1 rating (lowest primary energy usage). Energy consumption is expressed in kWh per square metre of floor area of the building per year (kWh/m2/year) and CO2 emissions are expressed in kilograms of carbon dioxide per square metre per annum (kgCO2/m2/year). For the purposes of this release A1, A2, and A3 have been combined because of the small number of Certificates in these categories. The certificate is valid for 10 years unless changes are made to the building.


Table Notes

Table 1 presents the number of BERs published by month since January 2009. A premises that has had BERs conducted in different years is included in each year. This table gives an overview of the number of BER assessments being performed each month.

Tables 2-14 only include the latest BER published for each building i.e. the BER is on the public register and is not expired - the number is lower than the total in Table 1 because expired and replaced certificates have been excluded.

Table 2 shows the number of BER certificates by energy rating and year.

Table 3 classifies the number of BER certificates by energy rating and building type. This relates to the current building use and it is displayed on the BER certificate. Some building types have been combined for the purposes of this release e.g. schools and colleges.

Tables 4-5 profile Building Energy Ratings by county and Dublin postal district. Table 4 is in county within province order.

Table 6 profiles Building Energy Ratings by type of main space heating system fuel. The heating system fuel options are: Mains gas; LPG; Biogas; Oil; Electricity; Coal; Biomass; Waste heat; Anthracite; Smokeless fuel; Dual fuel appliances; and Other. Categories with only a small number of responses have been amalgamated in Table 6.

Tables 7-8 cross-classify main space heating system fuel by county and building type.

Table 9 cross-classifies main ventilation system by building type.

Table 10 shows the average floor area by building type and county.

Tables 11-12 show the average primary energy use and average carbon dioxide figures by building type and county.

Table 13 shows the relationship between period of construction and building energy ratings. It can be linked with changes to the Building Regulations that require new buildings to be more energy efficient.

Table 14 cross-classifies main space heating fuel by period of construction.

upArrowHide Background Notes